SAVVY 1 NEMA 4X FPR housed panel for control of 120 VAC, 1ph. Series 32 1/2 HP mixers. Components include a circuit breaker, motor monitor with LED display, contactor, run, off, on, alarm status lamps, HOA switch, mechanical run time hour meter, and lightning surge arrester. UL Listed motor monitor includes high/low voltage trips, over-current/under-current trips, rapid cycling protection, and includes programmable time delay restarts.  The motor monitor provides reliable instantaneous protection against low voltage conditions and trips the motor if over-current or under-current set- points are exceeded.    The LED display supplies realtime data on motor amperage, voltage, and pending or current fault conditions.
SAVVY 3 NEMA 4X 316 S.S. housed panel for control of 460 VAC, 3ph. Series 32 & 32PT 2 - 25 HP mixers. Components include a fused disconnect switch, CPT, motor monitor with display, starter with adjustable amperage trip heaters, run, off, alarm status lamps, HOA switch, mechanical run time hour meter, and lightning surge arrester. Motor monitoring features include high/low voltage, voltage/current unbalance, phase loss or reversal, over/under current, rapid cycling, and includes programmable time delay restarts. Optional high motor temperature PT-100/SOLO system includes PT-100 (100 ohm RTD) and SOLO temperature monitor/controller.  The RM-2000 display keypad supplies realtime data on motor amperage, voltage, % unbalance and data-logging of last four fault conditions.
SAVVY 5 NEMA 4X FRP housed panel for VFD speed control of 460 VAC, 3ph. Series 32 & 32PT 2 - 25 HP mixers and INTRUDRRR series inline mixers.  Components include a fused disconnect switch, CPT, VFD with HIM keypad display, status lamps (run, off, and alarm), HOA switch, speed control knob, mechanical run time hour meter, and lightning surge arrester.   VFD features include high/low voltage, over/under current, and  high/low speed settings.   The HIM display keypad supplies realtime data on motor amperage, voltage, speed, and fault conditions. Remote input signal or local speed control. Output contacts provide information to remote scada systems.
Home Setting the Standard PDF Downloads Exchange Program Contact Us
SAVVY CIU CONTROL PANELS 
  SAVVY 1  230vac 1ph.
SAVVY 1 NEMA 4X FPR housed panel for control of 230 VAC, 1ph. Series 32 1 - 15 HP mixers or Series 32PT 2 - 15 HP mixers.
SAVVY 3 NEMA 4X 316 S.S. housed panel for control of 460 VAC, 3ph. Series 32 & 32PT 2 - 25 HP mixers and INTRUDRRR series inline mixers. Components include a MCP w/ disconnect switch, CPT, motor monitor with display, combination starter with adjustable amperage trip heaters, run, off, alarm status lamps, HOA switch, mechanical run time hour meter, and lightning surge arrester. Motor monitoring features include high/low voltage, voltage/current unbalance, phase loss or reversal, over/under current, rapid cycling, and includes programmable time delay restarts. Optional high motor temperature PT-100/SOLO system includes PT-100 (100 ohm RTD) and SOLO temperature monitor/controller.  The RM-2000 display keypad supplies realtime data on motor amperage, voltage, % unbalance and data-logging of last four fault conditions.
SAVVY 4 NEMA 4X FRP housed panel for control of 460 VAC, 3ph. Series 32 & 32PT 2 - 25 HP mixers and INTRUDRRR series inline mixers. Components include a fused disconnect switch, CPT, motor monitor with display, starter with adjustable amperage trip heaters, run, off, alarm status lamps, HOA switch, mechanical run time hour meter, and lightning surge arrester. Motor monitoring features include high/low voltage, voltage/current unbalance, phase loss or reversal, over/under current, rapid cycling, and includes programmable time delay restarts. Optional high motor temperature PT-100/SOLO system includes PT-100 (100 ohm RTD) and SOLO temperature monitor/controller.  The RM-2000 display keypad supplies realtime data on motor amperage, voltage, % unbalance and data-logging of last four fault conditions.
Products